Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
iScience ; 26(4): 106562, 2023 Apr 21.
Article in English | MEDLINE | ID: covidwho-2295366

ABSTRACT

This study reports the isolation and characterization of a human monoclonal antibody (mAb) called 19n01. This mAb was isolated by using single-cell RNAseq of B cells from donors infected with the ancestral strain. This mAb possesses a potent and broad capacity to bind and neutralize all previously circulating variants of concern (VOCs), including Omicron sublineages BA.1, BA.2, and BA.4/5. The pseudovirus neutralization assay revealed robust neutralization capacity against the G614 strain, BA.1, BA.2, and BA.4/5, with inhibitory concentration (IC50) values ranging from 0.0035 to 0.0164 µg/mL. The microneutralization assay using the G614 strain and VOCs demonstrated IC50 values of 0.013-0.267 µg/mL. Biophysical and structural analysis showed that 19n01 cross-competes with ACE2 binding to the receptor-binding domain (RBD) and the kinetic parameters confirmed the high affinity against the Omicron sublineages (KD of 61 and 30 nM for BA.2 and BA.4/5, respectively). These results suggest that the 19n01 is a remarkably potent and broadly reactive mAb.

2.
iScience ; 2023.
Article in English | EuropePMC | ID: covidwho-2260145

ABSTRACT

This study reports the isolation and characterization of a human monoclonal antibody (mAb) called 19n01. This mAb was isolated by using single-cell RNAseq of B cells from donors infected with the ancestral strain. This mAb possesses a potent and broad capacity to bind and neutralize all previously circulating variants of concern (VOCs), including Omicron sublineages BA.1, BA.2, and BA.4/5. The pseudovirus neutralization assay revealed robust neutralization capacity against the G614 strain, BA.1, BA.2, and BA.4/5, with IC50 values ranging from 0.0035 to 0.0164 μg/mL. The microneutralization assay using the G614 strain and VOCs demonstrated IC50 values of 0.013 to 0.267 μg/mL. Biophysical and structural analysis showed that 19n01 cross-competes with ACE2 binding to the RBD and the kinetic parameters confirmed the high affinity against the Omicron sublineages (KD of 61 and 30 nM for BA.2 and BA.4/5, respectively). These results suggest that the 19n01 is a remarkably potent and broadly reactive mAb. Graphical

3.
Echocardiography ; 39(7): 920-934, 2022 07.
Article in English | MEDLINE | ID: covidwho-2250258

ABSTRACT

BACKGROUND: Takotsubo syndrome is a clinical syndrome characterized by an acute and transient left ventricular systolic dysfunction related to an emotional or physical stressful event. CASE PRESENTATION: During the Covid-19 pandemic, five cases of Takotsubo syndrome in hospitalized, mechanically ventilated patients due critical SARS-CoV-2 infection have been identified at our institution. Here we present the electrocardiographic, echocardiographic and angiographic characteristics of this case series. All cases were initially suspected by echocardiography performed due an abnormal electrocardiogram, troponin elevation or clinical deterioration. CONCLUSION: A high index of suspicion should be sought to identify Takotsubo syndrome and other cardiac complications associated with SARS-CoV-2 infection.


Subject(s)
COVID-19 , Takotsubo Cardiomyopathy , COVID-19/complications , Echocardiography , Electrocardiography , Humans , Pandemics , SARS-CoV-2 , Takotsubo Cardiomyopathy/diagnosis , Takotsubo Cardiomyopathy/diagnostic imaging
4.
Transbound Emerg Dis ; 69(4): e734-e745, 2022 Jul.
Article in English | MEDLINE | ID: covidwho-1470482

ABSTRACT

The SARS-CoV-2 virus was detected for the first time in December 2019 in Wuhan, China. Currently, this virus has spread around the world, and new variants have emerged. This new pandemic virus provoked the rapid development of diagnostic tools, therapies and vaccines to control this new disease called COVID-19. Antibody detection by ELISA has been broadly used to recognize the number of persons infected with this virus or to evaluate the response of vaccinated individuals. As the pandemic spread, new questions arose, such as the prevalence of antibodies after natural infection and the response induced by the different vaccines. In Mexico, as in other countries, mRNA and viral-vectored vaccines have been widely used among the population. In this work, we developed an indirect ELISA test to evaluate S1 antibodies in convalescent and vaccinated individuals. By using this test, we showed that IgG antibodies against the S1 protein of SARS-CoV-2 were detected up to 42 weeks after the onset of the symptoms, in contrast to IgA and IgM, which decreased 14 weeks after the onset of symptoms. The evaluation of the antibody response in individuals vaccinated with Pfizer-BioNTech and CanSinoBio vaccines showed no differences 2 weeks after vaccination. However, after completing the two doses of Pfizer-BioNTech and the one dose of CanSinoBio, a significantly higher response of IgG antibodies was observed in persons vaccinated with Pfizer-BioNTech than in those vaccinated with CanSinoBio. In conclusion, these results confirm that after natural infection with SARS-CoV-2, it is possible to detect antibodies for up to 10 months. Additionally, our results showed that one dose of the CanSinoBio vaccine induces a lower response of IgG antibodies than that induced by the complete scheme of the Pfizer-BioNTech vaccine.


Subject(s)
COVID-19 , Viral Vaccines , Animals , Antibodies, Viral , COVID-19/prevention & control , COVID-19/veterinary , Immunoglobulin A , Immunoglobulin G , Immunoglobulin M , SARS-CoV-2 , Spike Glycoprotein, Coronavirus
SELECTION OF CITATIONS
SEARCH DETAIL